HPLC Columns (2 - 4 mm Internal Diameter)

SEPSERV Separation Service Berlin offers a wide range of HPLC columns.

For 4, 3, and 2 mm diameter SEPSERV uses the HYPERCHROME column system, which is widespread especially in Germany. On request packings will be delivered also in columns of all the other common systems.

For 1 mm-Microbore Columns the Mini-HYPERCHROME system with an integrated precolumn was developed by SEPSERV.

HPLC Column System HYPERCHROME

1

Column Tube

2

Stainless Steel Sieve 

3

Glass Fiber Filter

4

Teflon Ring

5

Column End Fitting

6

Column Head Nut

7

Stopper

8

Cartridge Holder

9

Gripp Protection

10

Precolumn Cartridge 10 mm

11

Double End Fitting

12

Distance Piece 

13

Capillary End Fitting

14

Precolumn Cartridge 5 mm

 

 

 

left:

Construction of a HPLC Column

center:

Cartridge Holder (8) with a 10 mm Precolumn Cartridge (10) and a Double End Fitting (11) (instead of the parts (6) and (5)in the left picture)

right:

If you use a 5 mm Precolumn Cartridge(14), part (5) must be changed against the Capillary End Fitting (13) and the Distance Piece (12).

If you use 20 mm Precolumn Cartidges, a lengthening hull is placed between the Column Tube (1) and the Cartridge Holder (8).

 

In order to protect the separation columns against pollution Precolumn Cartridges and Guard Columns are recommended.

For the realization of analyses with modern HPLC equipments in many cases the use of Narrowbore and Microbore Columns is of advantage.

Narrowbore and Microbore Columns

Using a modern HPLC equipment there is no need for conventional 4 mm columns in analytical scale. Already the transition from a 4 mm column to a 3 mm column can save up to 300.00 per month for solvents ! As shown in the example below, you need not even a "special" equipment.

Retention times, selectivities, plate numbers, prepressures and also the life time of small diameter columns do not alter in comparison to the corresponding 4 mm columns !

Small diameter columns from SEPSERV have the same quality as 4 mm columns.

With a modern analytical pump head and an analytical flow cell working with 3 mm separation columns is no problem.

For the use of 2 mm (Narrowbore)- and 1 mm (Microbore)-columns usually a microcell is necessary.

Save your money and protect the environment!

Example

          Flow Rate

Suitable for  ColumnÆ

Analytical Pump Head

0,020 - 5 ml/min

4, 3 and  2 mm

Micro-Pump Head

0.002 - 1 ml/min

2 and 1 mm

Analytical Cell

£ 10 µl cell volume

4, 3 and (2) mm

Microcell

£   1 µl cell volume

2 and 1 mm

 

 

 

Home

Survey

About SEPSERV

Catalogue

 

HPLC Columns

Special Columns

Environment

Food Stuffs

Biochemistry

Clinical Chemistry

.Pharmaceuticals

Chiralic Analysis

Ion Exchangers

OtherlSpeciallColumns

SelectivitylPacklTRIS

 

Ordering